• Link to Facebook
  • Link to LinkedIn
  • Link to X
  • 800-989-0057
  • Contact
Remington Medical
  • Our Products
    • Medical Cables
      • Pacing Cable (ADAP-2000)
      • Bi-Ventricular Pacing (BS-101-97)
      • Epicardial Pacing (FL-601-97)
      • EPG PSA Pacing Cable (S-101-97)
      • Disposable Surgical Cable (PA-801)
    • Medical Supply Devices
      • 600ml Drainage Bag
      • Bag Decanter
      • Locking Syringe
    • Medical Needles
      • Biopsy Needles
      • Chiba Needles
      • Franseen Needles
  • Contract Manufacturing
    • Product Lifecycle Management
      • Manufacturer of Record
    • Prototyping
      • Prototype Consulting
    • In-House Tool Shop
      • CNC Milling
      • EDM Machine Shop
    • Manufacturing
      • Assembly
      • Soldering
      • Ultrasonic Welding
      • Laser Marking
      • Pad Printing
    • Medical Packaging
      • Managed Sterilization
  • VascuChek®
  • Solutions
    • Cardiology
    • Cardiovascular Surgery
    • Cath Lab Solutions
    • General Surgery
    • Hospital System Solutions
    • Oncology
    • Urology Medical Devices
    • Vascular Access
  • Resources
    • Blog
    • Customer Resources
    • FAQ
  • About
    • Careers
    • Distributors
    • Our History
    • Regulatory
    • Our Process
  • Menu Menu

FAQs About CE Marking for Medical Devices

Understanding the CE marking process can be daunting.

CE Marking for Medical Devices

In this blog, we’ll answer the following FAQs about CE marking for medical devices:

  • What Is CE Marking for Medical Devices?
  • What Countries Require CE Certifications?
  • Do All Medical Devices Require a CE Mark?
  • What’s a Notified Body Assessment?
  • How Long Is a CE Valid?
  • What’s the Difference Between 510k and CE?
  • How Do I Get a CE Certification in the US?
  • What Is a Declaration of Conformity?
  • What Happens If a Product Isn’t CE Marked?
  • How Long Does It Take to Get a CE Certification?
  • Will Changing a Contract Manufacturer Impact My CE Certification?
  • How Does MDR 2017/745 Affect CE Marking?
  • Where Do You Place a CE Mark?

What Is CE Marking for Medical Devices?

A CE mark for medical devices is a label with the letters CE printed directly on the device, which means Conformité Européenne, or European conformity in French. Medical devices with CE markings have proven they comply with European requirements for safety, health, and environmental protection. The CE mark is not just about the letters. EU MDR 2017/745, Annex V depicts a specific font and spacing that must be used.

What Countries Require CE Certifications?

The CE mark is mandatory for medical devices to be sold in the following 29 member states of the European Union (EU):

  • Switzerland
  • Austria
  • Belgium
  • Israel
  • Turkey
  • Norway
  • Iceland
  • Serbia
  • Iceland
  • Bulgaria
  • Croatia
  • Republic of Cyprus
  • Czech Republic
  • Denmark
  • Estonia
  • Finland
  • France
  • Germany
  • Greece
  • Hungary
  • Ireland
  • Italy
  • Latvia
  • Lithuania
  • Luxembourg
  • Malta
  • Netherlands
  • Poland
  • Portugal

Do All Medical Devices Require a CE Mark?

CE marking is mandatory, even if the medical device was manufactured outside of the EU.

What’s a Notified Body Assessment?

A notified body is an essential part of the CE conformity process for certain products in the EU. Notified body organizations have the important task of assessing the conformity of products, reviewing technical files and test reports, and inspecting production facilities. Notified Bodies are designated by the EU. As such, they’re authorized to grant manufacturers certificates under the EU MDR 2017/745 which allow the manufacturers to apply the CE-mark to their products and gain access to the EU market.

How Long Is a CE Valid?

The validity period of CE certificates for medical devices is generally three years. However, for high-risk devices, this period may be as short as one year. The status of your CE certification also depends on your ability to maintain your quality system certification.

What’s the Difference Between 510(k) and CE?

A 510(k) is the regulatory pathway that medical device manufacturers must follow to gain clearance from the FDA to market devices in the U.S. On the other hand, a CE mark indicates that a medical device meets the safety, health, and environmental protection requirements set by the EU to commercialize devices in all 33 member states.

Are you looking to bring a medical device to the market in the United States? Check out our blog here about bringing your device to market in the US for more information.

How Do I Get a CE Certification in the US?

If you’re a medical device manufacturer based in the U.S., you’ll need to appoint an authorized representative in one of the member states to address documentation in the EU. To help you obtain a CE certification, the representative will verify your technical documentation, keep you informed throughout the process, and register a physical place for your notified body to receive device samples for inspections.

What Is a Declaration of Conformity?

The Declaration of Conformity is a crucial document signed by manufacturers or authorized representatives to ensure that medical devices sold in the EU meet the directives and regulations. However, the manufacturer mentioned in the document isn’t always the one who physically made the device. It could be their authorized representative or notified body who assumes this responsibility.

What Happens If a Product Isn’t CE Marked?

Illegally affixing the CE marking to a medical device or selling products that don’t meet EU regulations and harmonized standards can lead to serious consequences, such as products being removed from the market.

How Long Does It Take to Get a CE Certification?

The time it takes to obtain CE certification depends on a variety of factors, such as risk class of device, type of device, backlog of submissions at the notified body, etc. The actual time may range from a few months to a few years.

Will Changing a Contract Manufacturer Impact My CE Certification?

Yes. As the owner of the CE mark, you need to carefully select a new contract manufacturer based on the criteria outlined in your quality system. This system should outline how to qualify and continually assess suppliers. You also need to notify your local notified body about this change and request an updated CE certificate. It’s important to note that the notified body might even require an onsite audit of the new contract manufacturer before approving the change and issuing a new CE certificate. This all must be completed BEFORE placing products manufactured by the new CM on the EU market.

How Does MDR 2017/745 Affect CE Marking?

The EU passed 2023/607 in February 2023, which extended the implementation of EU MDR 2017/745 to December 31, 2027 for high risk devices and December 31, 2028 for lower risk devices. It also granted Notified Bodies the authority to provide extension letters for devices CE-marked under MDD 93/42/EEC and AIMDD 90/385/EEC all the way to the dates above.

Where Do You Place a CE Mark?

For reusable medical devices, the CE marking can be affixed on the back or underside of the device, as long as it’s visible and legible. To ensure readability, it must be at least 5 mm in height. However, for small devices or components, the minimum dimension requirement for the CE marking can be waived. However, when it comes to disposable medical devices, the CE mark isn’t required to be printed directly on the device. For single-use, disposable devices, the CE mark only has to be on the labeling.

Remington Medical’s laser marking solutions are non-intrusive, cause no corrosion, and stand up to the tests of time.

Our Laser Marking Solutions

Key Takeaways

CE marking indicates that your device complies with essential EU legal requirements, giving patients peace of mind that they’re using a safe device designed and tested to meet safety and performance standards.

With more than 30 years of experience in medical device manufacturing, Remington Medical knows a thing or two about MDR and FDA regulations. Contact us today, and one of our experienced professionals can answer any other questions you may have about the CE marking process.

  • Share on Facebook
  • Share on X
  • Share on LinkedIn

Remington Medical Named “Best Overall Medical Device Company” in MedTech Breakthrough Awards Program

Drainage Bags
Learn about common drainage bag failures, their causes, and how to prevent leaks with better design and materials.
May 7, 2026
https://remmed.com/wp-content/uploads/2026/05/Untitled-design-5-1.png 1148 2048 AbstraktMarketing /wp-content/uploads/2023/05/Remington-Logo-R-Dark.png AbstraktMarketing2026-05-07 08:07:582026-06-01 21:50:54Remington Medical Named “Best Overall Medical Device Company” in MedTech Breakthrough Awards Program
Common Drainage Bag Failures (and How to Prevent Them in Clinical Use-img

Common Drainage Bag Failures (and How to Prevent Them in Clinical Use)

Drainage Bags
Learn about common drainage bag failures, their causes, and how to prevent leaks with better design and materials.
March 2, 2026
https://remmed.com/wp-content/uploads/2026/03/Common-Drainage-Bag-Failures-and-How-to-Prevent-Them-in-Clinical-Use-img.jpg 1250 2000 AbstraktMarketing /wp-content/uploads/2023/05/Remington-Logo-R-Dark.png AbstraktMarketing2026-03-02 12:13:322026-06-01 21:50:54Common Drainage Bag Failures (and How to Prevent Them in Clinical Use)

What to Look for When Selecting the Right Disposable Pacing Cable

Disposable Medical Devices
Learn how to evaluate disposable pacing cables for safety, compatibility, and cost effectiveness to compare products with confidence.
February 17, 2026
https://remmed.com/wp-content/uploads/2025/07/Why-More-Hospitals-Are-Switching-to-Disposable-Pacing-Cables.jpg 1250 2000 AbstraktMarketing /wp-content/uploads/2023/05/Remington-Logo-R-Dark.png AbstraktMarketing2026-02-17 10:33:122026-06-01 21:50:54What to Look for When Selecting the Right Disposable Pacing Cable

Why Disposable Pacing Cables Are Safer for Patients and Staff

Disposable Medical Devices
Explore why disposable pacing cables are safer than reusable ones. Learn how single-use designs improve infection control, traceability, and compliance.
February 17, 2026
https://remmed.com/wp-content/uploads/2026/02/medical-worker-throwing-disposables-away.jpg 1250 2000 AbstraktMarketing /wp-content/uploads/2023/05/Remington-Logo-R-Dark.png AbstraktMarketing2026-02-17 08:47:102026-06-01 21:50:55Why Disposable Pacing Cables Are Safer for Patients and Staff

Why Choosing a U.S.-Based Contract Manufacturer Matters in a High-Tariff Trade Environment

Contract Manufacturing
 Learn how partnering with a U.S.-based contract manufacturer helps medical device OEMs reduce tariff exposure and limit import risks.
February 12, 2026
https://remmed.com/wp-content/uploads/2026/02/Why-Choosing-a-U.S.-Based-Contract-Manufacturer-Matters-in-a-High-Tariff-Trade-Environment.jpg 1250 2000 AbstraktMarketing /wp-content/uploads/2023/05/Remington-Logo-R-Dark.png AbstraktMarketing2026-02-12 12:55:342026-06-01 21:50:55Why Choosing a U.S.-Based Contract Manufacturer Matters in a High-Tariff Trade Environment

Cost Efficiency for Single-Use vs. Reusable Medical Drainage Bag Systems

Drainage Bags
Explore the true cost efficiency of medical drainage bag options by comparing single-use and reusable systems.
January 20, 2026
https://remmed.com/wp-content/uploads/2026/01/Cost-Efficiency-for-Single-Use-vs-clear.jpg 1250 2000 AbstraktMarketing /wp-content/uploads/2023/05/Remington-Logo-R-Dark.png AbstraktMarketing2026-01-20 08:27:222026-06-01 21:50:55Cost Efficiency for Single-Use vs. Reusable Medical Drainage Bag Systems
Foley catheter and urine drainage bag collect urine for disability or patient in hospital

How 600ml Medical Drainage Bag Stock Supports Emergency Care

Drainage Bags
Learn why a 600ml medical drainage bag is a critical emergency medical supply for hospitals. Explore storage, surge readiness, and best practices.
January 9, 2026
https://remmed.com/wp-content/uploads/2025/10/Foley-catheter-and-urine-drainage-bag-collect-urine-for-disability-or-patient-in-hospital.jpg 1250 2000 AbstraktMarketing /wp-content/uploads/2023/05/Remington-Logo-R-Dark.png AbstraktMarketing2026-01-09 07:21:552026-06-01 21:50:55How 600ml Medical Drainage Bag Stock Supports Emergency Care
Close up of medical drip or IV drip chamber

How Closed Fluid Systems Affects Medical Decanter Performance

Bag Decanter
More surgical teams are adopting closed-system fluid management. Learn why procurement teams are evaluating medical decanter solutions.
October 6, 2025
https://remmed.com/wp-content/uploads/2025/10/Close-up-of-medical-drip-or-IV-drip-chamber.jpg 1250 2000 AbstraktMarketing /wp-content/uploads/2023/05/Remington-Logo-R-Dark.png AbstraktMarketing2025-10-06 10:21:542026-06-01 21:50:55How Closed Fluid Systems Affects Medical Decanter Performance
Foley catheter and urine drainage bag collect urine for disability or patient in hospital

Top 5 Red Flags to Avoid When Buying Medical Drainage Bags

Drainage Bags
Purchasing medical drainage bags? Learn the red flags procurement professionals should avoid, from missing FDA certification to unreliable packaging.
October 6, 2025
https://remmed.com/wp-content/uploads/2025/10/Foley-catheter-and-urine-drainage-bag-collect-urine-for-disability-or-patient-in-hospital.jpg 1250 2000 AbstraktMarketing /wp-content/uploads/2023/05/Remington-Logo-R-Dark.png AbstraktMarketing2025-10-06 10:20:262026-06-01 21:50:55Top 5 Red Flags to Avoid When Buying Medical Drainage Bags
Previous Previous Previous Next Next Next

Categories

  • Bag Decanter
  • Biopsy Needles
  • Contract Manufacturing
  • Disposable Medical Devices
  • Drainage Bags
  • General Surgery
  • Healthcare Industry Trends
  • In House Manufacturing
  • Injection Molding
  • Medical Device CE Marking
  • Medical Device Development
  • Medical Needles
  • MedTech
  • Products
  • Remington Medical
  • Surgical Cables
  • Uncategorized
  • Urology
  • VascuChek

Contact Us

"*" indicates required fields

Opt-in to future marketing communication from Remington Medical

Get In Touch

Phone

Sales: 800-989-0057

Address

6830 Meadowridge Court
Alpharetta, GA 30005

Navigation

Our Products

Contract Manufacturing

Solutions

Resources

About

Instructions for Use

Symbols Glossary

Recent Blogs

  • Remington Medical Named “Best Overall Medical Device Company” in MedTech Breakthrough Awards Program May 7, 2026
  • Common Drainage Bag Failures (and How to Prevent Them in Clinical Use) March 2, 2026
  • What to Look for When Selecting the Right Disposable Pacing Cable February 17, 2026
Website by Abstrakt Marketing Group © 2025
  • Sitemap
  • Privacy Policy
  • Facebook
  • Linkedin
  • Twitter
Link to: How Are Medical Devices Classified Under EU MDR? Link to: How Are Medical Devices Classified Under EU MDR? How Are Medical Devices Classified Under EU MDR?Medical Devices Classified Under EU MDR Link to: How to Prepare a Medical Device Technical File Link to: How to Prepare a Medical Device Technical File Female doctor working on smart device in the medical office at the hospitalHow to Prepare a Medical Device Technical File
Scroll to top Scroll to top Scroll to top

This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies.

OKLearn more

Cookie and Privacy Settings



How we use cookies

We may request cookies to be set on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience, and to customize your relationship with our website.

Click on the different category headings to find out more. You can also change some of your preferences. Note that blocking some types of cookies may impact your experience on our websites and the services we are able to offer.

Essential Website Cookies

These cookies are strictly necessary to provide you with services available through our website and to use some of its features.

Because these cookies are strictly necessary to deliver the website, refusing them will have impact how our site functions. You always can block or delete cookies by changing your browser settings and force blocking all cookies on this website. But this will always prompt you to accept/refuse cookies when revisiting our site.

We fully respect if you want to refuse cookies but to avoid asking you again and again kindly allow us to store a cookie for that. You are free to opt out any time or opt in for other cookies to get a better experience. If you refuse cookies we will remove all set cookies in our domain.

We provide you with a list of stored cookies on your computer in our domain so you can check what we stored. Due to security reasons we are not able to show or modify cookies from other domains. You can check these in your browser security settings.

Other external services

We also use different external services like Google Webfonts, Google Maps, and external Video providers. Since these providers may collect personal data like your IP address we allow you to block them here. Please be aware that this might heavily reduce the functionality and appearance of our site. Changes will take effect once you reload the page.

Google Webfont Settings:

Google Map Settings:

Google reCaptcha Settings:

Vimeo and Youtube video embeds:

Accept settingsHide notification only

ADAP-2RL Cardiac Cable Adapter – IF-00010 Rev A

Name(Required)
Company Address

ADAP-2R Cardiac Cable Adapter – IF-00009 Rev A

Name(Required)
Company Address

ADAP-I Cardiac Cable Adapter – IF-00007

Name(Required)
Company Address

301-CG Cardiac Extension Cable Family – IF-00006 Rev A

Name(Required)
Company Address

BS-101 Cardiac Extension Cable Family – IF-00005 Rev A

Name(Required)
Company Address

Automatic Cutting Needles (NAC)

Name(Required)

VascuChek® Disassembly and Recycling Instructions

VascuChek® Disassembly and Recycling Instructions

VascuChek® Surgical IFU

Name(Required)
Company Address

Disposable Extension Cable Family – IF-00004 Rev A

Name(Required)
Company Address